di-Sodium+\u03B2-glycerophosphate+pentahydrate
Supplier:
VWR Chemicals
Description:
Duo indicator papers show two different colours for each pH value.
Catalog Number:
(7053.2500)
Supplier:
Avantor
Description:
Dichloromethane, BAKER ANALYZED® ACS, J.T.Baker®
UOM:
1 * 2,5 L
Supplier:
KARTELL
Description:
PS, transparent.
Catalog Number:
(MARI0611300)
Supplier:
MARIENFELD
Description:
Counting chambers according to Sedgewick for particles and microorganisms in transparent liquids.
UOM:
1 * 1 items
Catalog Number:
(216-1467)
Supplier:
KARTELL
Description:
PP, white.
UOM:
1 * 1 items
Supplier:
DWK LIFE SCIENCES
Description:
These gas distribution tubes are designed for reactions between gases and liquids. They are made of clear DURAN® borosilicate glass 3.3.
Catalog Number:
(IKAAU098950)
Supplier:
IKA JANKE KUNKEL
Description:
Powerful, mechanically controlled agitators for intensive mixing with approval for use in Ex-Zone 1 (2G), temperature class T3 acc. to the ATEX 95 directive.
UOM:
1 * 1 items
Supplier:
TINTOMETER
Description:
Lovibond® Comparator system 2000+ is an extremely versatile, modular system for testing water. The battery operated portable lighting unit can be integrated to give standardised lighting conditions to enhance reproducibility.
Supplier:
HACH
Description:
IntelliCALâ„¢ LDO101 is a digital, luminescent dissolved oxygen (LDO) electrode which is ideal for measuring dissolved oxygen in wastewater, drinking water and general water quality applications.
Catalog Number:
(115-0561)
Supplier:
KIMBERLY CLARK
Description:
These Microfiber Wipers are designed for high end optical lens cleaning in a laboratory environment. They are are heavier than the original KIMTECH SCIENCE* Wipers, so they are ideal for equipment or surface cleaning where more strength is needed. Thanks to their material they will not scratch delicate surfaces.
UOM:
1 * 600 items
Supplier:
LABCONCO
Description:
All RapidVap® Vertex™ Dry Block evaporators require a Block (not included). Blocks of solid aluminum include stainless steel handles to lift the block in and out of the evaporator. A 0,21" (0,5 cm) diameter port in the upper left hand corner of the block is provided for insertion of the temperature probe to monitor upper block temperature.
Catalog Number:
(444-0960)
Supplier:
BARNSTEAD THERMOLYNE
Description:
This sleek compact design unit is capable of rolling multiple size tubes or bottles for applications like cell culture, hybridisation assays and liquid mixing. The anti-corrosive, wear-resistant construction enables use in humid and COâ‚‚ environments.
UOM:
Supplier:
IKA JANKE KUNKEL
Description:
The HBC circulating baths have a high-quality stainless steel bath, an extended temperature range for tempering fluids in open and covered water baths up to 200/250 °C. The LED/ graphic TFT Display illustrates all relevant process parameters. The large surface of the radiator allows for an optimum heat exchange and a smooth warming of the medium. Units feature push and turn buttons for intuitive menu navigation. All models conform to the highest safety classification III (FL) for use with flammable liquids according to DIN 12876. HBC immersion circulators ensure short heating up times and have a temperature stability of ±0,01 /0,02 K ( basic/control model). The units have an integrated cooling coil, adjustable safety circuit and a front drain valve for safe emptying. To drain the system, a separate valve helps to avoid direct contact with fluid.
Catalog Number:
(630-1937)
Supplier:
VWR Collection
Description:
Upright microscope for brightfield and fluorescence observations with IOS N-plan objectives. Ideal for routine laboratory applications.
UOM:
1 * 1 items
Supplier:
VWR Collection
Description:
The VWR® LTS compatible pipettors reduce ejection force with a unique positive stop technology. This technology along with lighter plunger springs, a durable light weight design, and a comfortable handle design with perfect symmetry makes this the best choice for a lab trying to improve ergonomics.
Supplier:
HICHROM
Description:
Everest columns have unique selectivity and sensitivity, which are the result of bonding technology that improves C18 surface coverage and deactivates residual silanols. Previously, the 300 Å C18 chemistries had carbon coverage in the 2,8 to 3,6 µmol/m² range. Everest C18 coverage is in excess of 4 µmol/m² and approximates the theoretical limit based on surface area. The increased shielding of the base silica increases column lifetime and reduces the amount of TFA required to shield the silica.
Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the
![]()
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the
![]()
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at eurega_services@eu.vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
This product is no longer available. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service at 1-800-932-5000.
|
|||||||||